User's Manual

Table Of Contents
FWPP-501-01 Issue 1320000117795 Rev A FlexWave Prism Remote Unit and HDM RF Module Installation Guide
© March 2016 CommScope, Inc. Page 69
Install the Prism Remote Unit
CONNECT THE ANTENNA CABLE
CoaxialantennacablesmustberoutedfromtheantennatothePRU.Thecablesmustbeterminated
withanN-TypemaleconnectorforconnectiontothePRUantennaportorthelightningsurge
suppressor(accessory).
CAUTION! The antenna(s) used for this transmitter must be fixed-mounted on (outdoor/indoor)
permanent structures. RF exposure compliance is addressed at the time of licensing, as
required by the responsible FCC Bureau(s), including antenna co-location requirements of 47
CFR. 1.307(b)(3).
Usethefollowingproceduretoinstalltheantennacable(s).Thisprocedurerequiresthatyouconnect
cabletooneAntennaconnectoratatime.
1 Referto"UnderstandingRFCableRules”onpage26tounderstandtherelationshipbetweenantenna
numbersandRemoteRFmodules;thisinformationmakessureyouconnecttheAntennaconnectors
correctly.
2 RemovethedustcapfromanN-typefemaleAntennaconnectorlocatedontheundersideoftheunit,
asshownbelow.IfyouneedtoinstallcablestomorethanoneAntennaconnector,startintherear
andworkforward,applyingthecorrecttorqueasyoumakeeachconnection.Workingfromtherear
portoutprovidesyouwiththespaceyouneedtoapplythecorrecttorque.
N-type female
Antenna port
for Module A
Antenna
cable
Lightning
Surge Suppressor
(ships with RF Module)
Surge port
connector
Boom View of PRU