User's Manual
Table Of Contents
- Document Overview
- Overview of Prism Remote Units
- Overview of RF Modules for Prism Remote Units
- Configuring the System with RF
- Install the Prism Remote Unit
- Planning for a Prism Remote Unit Installation
- Unpack and Inspect the Prism Remote Unit and Components
- Mount the Prism Remote Unit
- Ground the PRU Chassis
- Connect a Network Cable to the PRU Chassis
- Connect Fiber Cable to the PRU Chassis
- Connect the Antenna Cable
- Connect the Power Wiring
- Determine the Circuit Breaker or Fuse for the PRU
- (Optional) Connect the Prism Remote Unit to a UPS
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Fan Module Maintenance
- Specifications
- Standards Certification
- DCCS Global Technical Support

FWPP-501-01 Issue 1 • 320000117795 Rev A FlexWave Prism Remote Unit and HDM RF Module Installation Guide
© March 2016 CommScope, Inc. Page 115
Specifications
SPECIFICATIONS
ThefollowingspecificationspertaintothePRUhardwarecomponents;forinformationonRFand
opticalspecificationsandthefrequencyandcompositeoutputpowerattheAntennaport,seethe
FlexWavePrismPerformanceSpecificationsthatcorrespondtotheFlexWavesoftwarereleasemanaging
thisPRU.
Table 25. Prism Remote Unit Technical Specifications
Parameter Specification Remarks
Enclosure dimensions See Table 19 on page 31
Weight See Table 18 on page 31
Mounting Wall, Pole, Inside Pole, and Vault
Outside Ambient
Temperature Rating -40° C to +50° C (-40º F to +122º F)
Storage Temperature -40° C to +70° C (-40º F to +158º F)
Humidity 10% to 90% non-condensing
Weather Resistance IP-65 Indoor or outdoor installation
Lightning Protection 20kA IEC 1000-45 8/30 ìs Waveform Provided by external lig
htning protector,
which is an accessory.
Cooling Fan Fan, IP-55
Operating Voltage Range 10 - 28 Vdc
Connectors
Network port RJ-45 female connector
AC power connector Sealed 3-pin Connection point for the AC power cable
Antenna cable connector 50 ohm N-Type (female) 50 ohms input/output impedance
Voltage input
AC-Powered PRUs 100 to 240 Vac, 50 to 60 Hz Operating range 90 to 265 Vac
DC-Powered PRUs -40 to -60 Vdc
Current rating
AC-Powered PRUs 15 AMPS
DC-Powered PRUs 45 AMPS