User's Manual
Table Of Contents
- Document Overview
- Overview of Prism Remote Units
- Overview of RF Modules for Prism Remote Units
- Configuring the System with RF
- Install the Prism Remote Unit
- Planning for a Prism Remote Unit Installation
- Unpack and Inspect the Prism Remote Unit and Components
- Mount the Prism Remote Unit
- Ground the PRU Chassis
- Connect a Network Cable to the PRU Chassis
- Connect Fiber Cable to the PRU Chassis
- Connect the Antenna Cable
- Connect the Power Wiring
- Determine the Circuit Breaker or Fuse for the PRU
- (Optional) Connect the Prism Remote Unit to a UPS
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Fan Module Maintenance
- Specifications
- Standards Certification
- DCCS Global Technical Support

FlexWave Prism Remote Unit and HDM RF Module Installation Guide 320000117795 Rev A • FWPP-501-01 Issue 1
Page 114 © March 2016 CommScope, Inc.
Fan Module Maintenance
9 RemovetheoldFanModulefromthePRU:
a TheFanModulehastwokeyholerivetsthatextendthroughtheirdesignatedslotsintothesheet
metalframe.TodisengagetheFanModulekeyholerivets,slidetheFanModuleforward
approximately1/4-inch.
b LifttheFanModulestraightuptoremoveitfromthePRUchassis.
10 LowertheFanModuleintothePRUfromthetop.EnsurethatthetwokeyholerivetsonthenewFan
Moduleextendthroughtheirdesignatedslotsinthesheetmetalframe,andthenslideFanModule
backapproximately1/4-inchtoengageitskeyholerivets.
11 AlignandtheninserttheFanModule’stwocaptivescrewswithnutsonthePRU;ensurecorrect
threadengagement,andthentightentheFanModule’scaptivescrews.
12 InserttheFanModulepowercablesothatthecableisdirectedtotheleftoftheconnector.Usethe
keytoalignthecablecorrectly.Donotuseexcessiveforcetomatethereceptacletotheplug.
CAUTION! Failure to align the Fan Module power cable correctly may cause damage to the PRU power
connectors, which could result in needing to replace the PRU chassis.
13 Useyourfingerstoturnthecouplingnutonthepowercableapproximately2-1/2revolutions,and
thentightenthecouplingnutanother1/4revolution.
14 TightenthetwocaptivescrewsthatsecuretheFanModuletothechassis;torquethescrewsto10
IN-LBS±1IN-LB.
15 ClosetheFanModulecoverandtightenitstwocaptivescrews;torquethescrewsto10IN-LBS±1
IN-LB.
Top of Prism Remote Unit
Two capve screws
Power cable