FWPP-501-01 Issue 1320000117795 Rev A FlexWave Prism Remote Unit and HDM RF Module Installation Guide
© March 2016 CommScope, Inc. Page 65
Install the Prism Remote Unit
Option C: ProAx Connector (Legacy AC-Powered PRUs)
NOTE: Use the following procedure to install the fiber cables using a legacy ProAx Connector.
If the PRU that you are installing has a Hardened Multi-Fiber Optic Connector, follow the
procedure in "Option A: Hardened Multi-Fiber Optic Connector” on page 55
If the PRU that you are installing has a Fiber Pass-Through Connector, follow the procedure
in "Option B: Fiber Pass-Through Connector” on page 61.
NOTE: The ProAx Connector will become obsolete effective 31 May 2013, and will not be used in
PRUs manufactured after 31 May 2013.
NOTE: DC-powered PRUs do not have a ProAx connector option.
APRUwiththeProAxConnectorconfigurationrequiresthepurchaseofaProAxcableassemblyforthe
PrismtointerfacewiththeOSPfiber.ThefibercableconnectorisaBX.5four-portfiberconnector,as
showninthefollowingpicture: