User's Manual
Table Of Contents
- Document Overview
- Overview of Prism Remote Units
- Overview of RF Modules for Prism Remote Units
- Configuring the System with RF
- Install the Prism Remote Unit
- Planning for a Prism Remote Unit Installation
- Unpack and Inspect the Prism Remote Unit and Components
- Mount the Prism Remote Unit
- Ground the PRU Chassis
- Connect a Network Cable to the PRU Chassis
- Connect Fiber Cable to the PRU Chassis
- Connect the Antenna Cable
- Connect the Power Wiring
- Determine the Circuit Breaker or Fuse for the PRU
- (Optional) Connect the Prism Remote Unit to a UPS
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Fan Module Maintenance
- Specifications
- Standards Certification
- DCCS Global Technical Support

FWPP-501-01 Issue 1 • 320000117795 Rev A FlexWave Prism Remote Unit and HDM RF Module Installation Guide
© March 2016 CommScope, Inc. Page 107
Install the RF Module(s)
CLOSE THE REMOTE UNIT DOOR AND SOLAR SHIELD
1 Donotslamthedoortocloseit—gentlyswingthedoorshutandpressitfirmlyclosed.
2 Slowlycloseeachdoorlatchinasmoothfluidmotion—donotallowthedoorlatchestosnapclosed.
Forbestresults,startingwiththetoplatchandworkingdowntothebottomlatch,useaflat-head
screwdrivertocloseeachlatchasshownbelow.
3 DonotslamtheSolarShieldtocloseit—gentlyswingitshutandpressitfirmlyclosed.
CAUTION! Service personnel must confirm that the perimeter gasket and door-to-door gaskets are in
place when closing the Remote Unit doors after servicing.
CAUTION! If the PRU door was allowed to snap closed, RF output from an HDM RF Module may be
disabled for up to three minutes. Any alarms generated immediately following the
opening/closing of the PRU Doors, such as Door Open, RF Power Low, System VSWR Fault, and
LPA VSWR Fault, automatically clear once the RF has recovered. If alarms do not clear after
three minutes, please contact CommScope for technical support; see "DCCSGlobalTechnical
Support”onpage119.
Solar Shield Door
Door latch