Install the Prism Remote Unit
7 AttachthestrengthmemberfromtheFiberOpticcabletotheStrain-Relieflugontheinsidebottom
ofthePRU.
8 TightentheexternaldomenutofthePass-ThroughConnectoraroundtheFiberOpticcable—torque
thedomenutto44in-lbsplusorminus4in-lbs.
9 RoutethefibercablefromtheundersideofthePRUtotheOSPbox.
10 Followlocalpracticestosecurethefibercableinplace.
11 (Optional)OneSFPsupportsupto12timeslotswith75MHzofbandwidth.Ifasecondfibercable
assemblyisrequired(forexample,yourPrismsystemhasthreeSFPstohandleupto280MHzofRF
bandwidth),completeStep3onpage61throughStep10onpage64toaddthesecondfibercable
assembly,onlythistime,connecttotheFiber2connectorlocatedatthebottomofthePRUasshown
inStep4onpage62.
12 Returntothemaininstallationprocessandcontinueat"ConnecttheAntennaCable”onpage69.