User's Manual
Table Of Contents
- Document Overview
- Overview of Prism Remote Units
- Overview of RF Modules for Prism Remote Units
- Configuring the System with RF
- Install the Prism Remote Unit
- Planning for a Prism Remote Unit Installation
- Unpack and Inspect the Prism Remote Unit and Components
- Mount the Prism Remote Unit
- Ground the PRU Chassis
- Connect a Network Cable to the PRU Chassis
- Connect Fiber Cable to the PRU Chassis
- Connect the Antenna Cable
- Connect the Power Wiring
- Determine the Circuit Breaker or Fuse for the PRU
- (Optional) Connect the Prism Remote Unit to a UPS
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Fan Module Maintenance
- Specifications
- Standards Certification
- DCCS Global Technical Support

FlexWave Prism Remote Unit and HDM RF Module Installation Guide 320000117795 Rev A • FWPP-501-01 Issue 1
Page 78 © March 2016 CommScope, Inc.
Install the Prism Remote Unit
(OPTIONAL) CONNECT THE PRISM REMOTE UNIT TO A UPS
Thefour-pinAUXConnectoronthebottomofthePRUallowsthePRUtobeconnectedtoanexternal
devicewithdrycontactconnections,suchasaUninterruptedPowerSupply(UPS).TheAUXConnector
pinsareshowninFigure17.
NOTE: The Normally Open (NO) or Normally Closed (NC) options are configurable in the GUI; see the
“Manage Contact Alarms” section of the current EMS System Setup and Provisioning Guide.
Figure 17. AUX Connector Pin Orientation
NOTE: The Major/Minor setting of the AUX Connector pins cannot be configured in the Prism 6.x
EMS GUI. In Prism 7.x, you can configure the Contact Alarm as Major or Minor (Alarms >
Manage Contact Alarms).
1
2
4
3
AUX Connector
Boom of PRU
Pin # Contact Color Alarm Input
1 NO/NC Brown Major External Alarm Input
2 CO White
3 NO/NC Blue Minor External Alarm Input
4 CO Black