User's Manual
Table Of Contents
- Document Overview
- Overview of Prism Remote Units
- Overview of RF Modules for Prism Remote Units
- Configuring the System with RF
- Install the Prism Remote Unit
- Planning for a Prism Remote Unit Installation
- Unpack and Inspect the Prism Remote Unit and Components
- Mount the Prism Remote Unit
- Ground the PRU Chassis
- Connect a Network Cable to the PRU Chassis
- Connect Fiber Cable to the PRU Chassis
- Connect the Antenna Cable
- Connect the Power Wiring
- Determine the Circuit Breaker or Fuse for the PRU
- (Optional) Connect the Prism Remote Unit to a UPS
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Fan Module Maintenance
- Specifications
- Standards Certification
- DCCS Global Technical Support

FlexWave Prism Remote Unit and HDM RF Module Installation Guide 320000117795 Rev A • FWPP-501-01 Issue 1
Page 70 © March 2016 CommScope, Inc.
Install the Prism Remote Unit
3 Connectalightningsurgesuppressortotheantennaport;torqueto8±1in-lbstoensurefull
connection.
NOTE: Lightening surge suppressor(s) ship with every RF Module. If the RF modules are populated in
the PRU from the factory, the lightening surge suppressors are in the Prism shipping crate. If
the RF Module is shipped individually, the lightening surge suppressor is shipped within the
RF Module shipping container.
4 IfthePRUhasaaDual20WSMR800/PCS1900RFModule(FWP-441T841MOD),youmustinstall
aFlexWaveNotchFilter(FWP-SPRINTFILTER)betweenthePRUandtheantennatoprovide
protectionfromspuriousemissionsinthePublicSafetybandbelow861.35MHzandtheCellular
bandabove869.5MHz.ForinformationonhowtoinstallaNotchFilter,goto"FlexWaveNotchFilter
(FWP-SPRINTFILTER)”onpage108.
5 Ensurethatthechassisgroundwireisinstalledcorrectly(see"GroundthePRUChassis”on
page52).Formaximumprotection,thesystemgroundwiremustbeattachedtoalowimpedance
groundsystem.
6 RoutethecoaxialantennacablefromtheantennatotheundersideofthePRU.
7 CuttheantennacabletotherequiredlengthandterminatewithanN-typemaleconnector.
8 Connecttheantennacabletothelightningsurgesuppressorortotheantennaport;apply15in-lbs
(1.7Nm)oftorque.
CAUTION! The antenna cable connections must be weather proofed (sealed) for outdoor installations.
9 RepeattheStep2throughStep8fortheremainingantennacables.
CONNECT THE POWER WIRING
ThePRUsupportsbothACandDCpower.Followthestepsappropriatetoyoursystemconfiguration:
• "Option1:ConnecttheACPowerWiring”onpage70
• "Option2:ConnecttheDCPowerWiring”onpage73.
Option 1: Connect the AC Power Wiring
A15-foot,3-wirecablewithconnectorsisprovidedfortheACpowerconnections.Theconnectorend
ofthecableconnectstotheACpowerportlocatedonthebottomoftheunit.Thestubendofthecable
mustberoutedtoanexternaljunctionbox(notprovided)forpermanentconnectiontotheACpower
systemwiring.IfthecablemustbeterminatedwithaplugtoconnecttotheACadapter,theplugmust
beprovidedbytheinstaller.
TheACpowersourcemustsupplybetween100and240Vac,50or60Hz,single-phasepowerthrough
acircuitbreakerorfuse.TheACpowercableprovidesthreewireleadsforline,neutral,andground
connections.Thepowercableisratedforindoororoutdooruseandmustnotbeplacedwithinelectrical
conduitasthiswillimpedethecoolingofthecableduringusage.Theelectricaljunctionboxandany
conduit,wire,andfittingsrequiredmustbeprovidedbytheinstaller.
CAUTION! Use extreme caution when working with high voltage AC power. Ensure all power is
disconnected before working on power circuits.