User's Manual

FlexWave Prism Remote Unit and HDM RF Module Installation Guide 320000117795 Rev AFWPP-501-01 Issue 1
Page 46 © March 2016 CommScope, Inc.
Install the Prism Remote Unit
Pole Mount Installation Using Bolts
CAUTION! This section describes how to secure a PRU to a wood pole using bolts. In high earthquake risk
areas, CommScope advises in addition to bolting, banding should be used redundantly to
ensure mechanical mounting capable of surviving severe seismic activity. Typical areas where
this attachment method are suggested are Earthquake Risk Zone 4, per Bellcore GR-63-CORE,
section 4.4.1.1. If you have application specific questions, consult the Wireless Technical
Assistance Center (TAC) for technical assistance (see "DCCS Global Technical Support” on
page 119). For information on banding, see "Steel Pole Installation Using Steel Banding” on
page 43.
1 Referto"MountingCautions”onpage42beforebeginningthisprocess.
2 LocatetheMountingBracket
providedwiththePRU
MountingKitandobtainthe
toolsandsupplieslistedin
"ToolsRequiredforAll
MountingMethods”onpage36
and"AdditionalToolsand
SuppliesRequiredfor
Wood-PoleMounting”on
page37.
3 EstablishwheretheMounting
Bracketwillbemountedonthe
poleandthendeterminethe
locationofthebracket
mountingboltsonthepoleand
markholelocationsonpole.
4 Drilla1/2-inchhole(equalto
diameterofthrough-bolt)into
theutilitypoleatthepoints
markedinStep3.
5 Securethebrackettotheutility
poleusingtwothrough-bolts,
washers,andnutsasshownin
thefollowingillustration,and
thentightenthenutssecurely.
6 Followthestepsin"Installinga
PRUontheMountingBracket”
onpage51.
Pole-mounng
bracket
Through-bolts
Nuts
and
washers
Nuts
and
washers