User's Manual

FWPP-501-01 Issue 1320000117795 Rev A FlexWave Prism Remote Unit and HDM RF Module Installation Guide
© March 2016 CommScope, Inc. Page 31
Install the Prism Remote Unit
Figure9onpage32throughFigure12onpage35providethespacingdimensionsforbandsand
bracketmountingbolts.
Table 18. Prism Remote Unit Weights
(1)
PRU Model Unpopulated Populated
Single-Bay
Pounds
K
ilograms
65 83
29 38
Dual-Bay
Pounds
K
ilograms
81 117
37 53
Tri-Bay
Pounds
K
ilograms
97 151
44 68
Quad-Bay
Pounds
K
ilograms
116 188
53 85
(1) “Unpopulated” weight includes the SeRF
M
odule and the Solar shields, which are always
present. “Populated” weight is the weight of
the chassis that has the SeRF Module and RF
Modules installed.
Table 19. Prism Remote Unit Enclosure Dimensions
(1)
PRU Model
Height Width
(2)
Depth
See…
Single-Bay
Inches
C
entimeters
25.2 12.211.2
64 30.9928.45
Figure 9 on page 32
Dual-Bay
Inches
C
entimeters
33.2 12.211.2
84.3 30.9928.45
Figure 10 on page 33
Tri-Bay
Inches
C
entimeters
41.2 12.2 11.2
104.6 30.9928.45
Figure 11 on page 34
Quad-Bay
Inches
C
entimeters
52.4 12.2 11.2
133.10 30.99 28.45
Figure 12 on page 35
(1) To have adequate clearance to open the PRU chassis
door, allow a minimum of 18
inches at the left, right and front of each PRU.
(2) Dimension for width includes the mounting
brackets.