User's Manual

FlexWave Prism Remote Unit and HDM RF Module Installation Guide 320000117795 Rev AFWPP-501-01 Issue 1
Page 30 © March 2016 CommScope, Inc.
Install the Prism Remote Unit
Mounting Plans
ThePRUhasalowprofiledesignthatrequiresminimalrealestateforinstallation.Thebasicdimensions
andweightsofthePRUarelistedinTable19onpage31andTable18onpage31.
ThePRUshouldbemountedonautilitypole,mast,oronaflatsurface.AMountingBracketshipswith
eachRemote.Installationconsistsofsecuringthebrackettothemountingsurface(wood,concrete,or
steel)andthenhangingtheunitfromthebracket.thePRUshouldonlybemountedinarestrictedaccess
location.
BeforemountingthePRU,makesurethatthefollowingrequirementsaremet.
ThePRUmust
beinstalledonlyinarestricted-accesslocation
mustbelocatedasspecifiedinthesystemdesignplan(notdocumentedhere).Ifasystemdesign
planhasnotbeenprepared,consultwiththeTechnicalSupportforWirelessProductsteamfor
assistance(see"DCCSGlobalTechnicalSupport”onpage119).
musthavereadyaccesstothespecifiedACorDCpowersource.
IfyoumountthePRUinahorizontalposition,youmustmountitataslightangle,withthetopofthe
PRUchassisangledhigherthanthebottom,whichcreatesaslopethatallowswaterorsnowtorun
offthePRUchassis.Ifitismountedindoors,nosloperequired.
IfyoumountthePRUinanupside-downhorizontalposition(i.e.,aceilingmount),attachsafety
leashesthatcansupporttheweightofafullypopulatedchassis(seeTable18onpage31).
Thesitechosenmust
conformtoalllocalcodes;requiredpermitsmustbeobtainedpriortomountingaPRU
complywiththeunitenvironmentalspecifications
beopentofreeairspaceonthebottom(cableentryend),thetop,thefront,andbothsides
allowadequateclearanceatthebottomofthePRUtoprovideaccessforattachingcablesandfor
viewingtheLEDindicator
provide18inches(45.7cm)ofclearanceonthefrontandbothsidesofthePRUtoallowdoors
tobeopenedforserviceandtoallowfreeaircirculation
beabletobearthesizeandweightofthePRUenclosure,seeTable19onpage31andTable18
onpage31