FWPP-501-01 Issue 1 • 320000117795 Rev A FlexWave Prism Remote Unit and HDM RF Module Installation Guide
© March 2016 CommScope, Inc. Page 21
Overview of RF Modules for Prism Remote Units
LEDS on Narrowband HDM RF Modules
Ref # LED LED Color Description
1 DPM Power
Green HDM RF Module is powered on.
Red Problem with the HDM RF Module power.
2 FPGA Status Blinking Green Blinks as heartbeat of the HDM RF Module.
3
LVDS 0 Status
Green Primary LVDS Dynamic Phase Alignment (DPA)
connector is operating as expected.*
Red Primary LVDS DPA connector is not operating as expected.
4
LVDS 1 Status
Green Primary LVDS Dynamic Phase Alignment (DPA) connector is operating as expected.*
Red Primary LVDS DPA connector is not operating as expected.
5 DSP/GC Status — Not used.
6 FPGA Load Status
Red FPGA is in startup mode.
Off FPGA load is complete.
7 TXA Status
Green All synthesizers are locked.
Blinking Green One or more synthesizer is unlocked.
Red Overflow on RX.
8 RXA Status
Green All synthesizers are locked.
Blinking Green One or more synthesizer is unlocked.
Red Overflow on RX.
9 TMA A Status — Not used.
10 TXB Status
Green All synthesizers are locked.
Blinking Green One or more synthesizer is unlocked.
Red Overflow on RX.
11 RXB Status
Green All synthesizers are locked.
Blinking Green One or more synthesizer is unlocked.
Red Overflow on RX.
12 TMA A Status — Not used.
* LED is only applicable to the Primary connector; it is no
t tied to the status of the Secondary DPA connector.