© March 2016 CommScope, Inc. Page 11
Overview of Prism Remote Units
SeRF Module LEDs
NOTE: The SeRF Module LEDs automatically enter a LED Roll Test sequence (cycle through its colors)
when the SeRF FPGA is loaded (approximately 4 minutes after initial power up) or when a
SeRF synthesizer failure occurs. The LED Roll Test sequence takes approximately two seconds
to complete, and cycles the ALARM, SYNTH, and STATUS LEDs, after which the LEDs begin
normal operation. Additionally, an active SeRF Synthesizer failure causes the same LED
sequencing approximately every minute until the SeRF failure clears.
LED LED
Color
Description
POWE
R
• GREEN • Power OK and operating properly
•
RED • Power supply out of tolerance
•OFF •No power present
STATU
S
•GREEN
•R
ED
• No alarm for the SeRF II Module
• Initial bootup sequence and should become GREEN within 1 minute;
if RED after bootup, a Major alarm exists for the SeRF Module
SYNTH
•GREEN •Locked
•
RED • Unlocked or is in initial bootup sequence
ALAR
M
• GREEN • No major alarm is present in the PRU or
in any downstream unit
• RED • Initial bootup sequence, or a major alarm is present in the PRU or in any downstream
unit
SeRF Module