User's Manual
Table Of Contents
- Document Overview
- Overview of RF Modules for Prism Remote Units
- RF Module Components
- RF Group Assignments for PRU RF Module Bays
- Understanding RF Cable Rules
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Standards Certification
- Accessing User Documentation on the TE Customer Portal
- Contacting TE Connectivity
Page 46 FlexWave Prism Remote Unit RF Module Installation Guide
©2015 TE Connectivity TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015
Close the Remote Unit Door and Solar Shield
1 Do not slam the door to close it—gently swing the door shut and press it firmly closed.
2 Slowly
close each door latch in a smooth fluid motion—do not allow the door latches to snap closed. For best
results, starting with the top latch and working down to the bottom latch, use a flat-head screwdriver to close
each latch as shown below.
3 Do
not slam the Solar Shield to close it—gently swing it shut and press it firmly closed.
Solar Shield
Door
Door latch
CAUTION! Service personnel must confirm that the perimeter gasket and door-to-door gaskets are in place when
closing the Remote Unit doors after servicing.
CAUTION! If the PRU door was allowed to snap closed, RF output from an HDM RF Module may be disabled for up
to three minutes. Any alarms generated immediately following the opening/closing of the PRU Doors,
such as Door Open, RF Power Low, System VSWR Fault, and LPA VSWR Fault, automatically clear once
the RF has recovered. If alarms do not clear after three minutes, please contact TE for technical support;
see “Contacting TE Connectivity” on page 51.
Provision the Prism Remote Unit
Refer to the current EMS System Setup and Provisioning Guide for information on configuring the PRU for a
FlexWave Prism system.