User's Manual
Table Of Contents
- Document Overview
- Overview of RF Modules for Prism Remote Units
- RF Module Components
- RF Group Assignments for PRU RF Module Bays
- Understanding RF Cable Rules
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Standards Certification
- Accessing User Documentation on the TE Customer Portal
- Contacting TE Connectivity
Cable Connecons for an HDM RF Module
TX0/RX0
TX1/RX1
POWER
DATA 1 (DIV)
DATA 0 (PRIM)
Cable Connecon Notes
• Always connect the Power cable.
• Always connect the two LVDS cables: PRIM and DIV.
• SISO requires one RF cable (TX0/RX0).
• MIMO and Dual-Band require two RF cables
(TX1/RX1 and TX0/RX0).
FlexWave Prism Remote Unit RF Module Installation Guide Page 39
TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015 ©2015 TE Connectivity
CAUTION! Ensure that all cable bends are below the top edge of the Connector Interface Panel as indicated by the
dashed line in the preceding figure. Failure to correctly position the cables could inhibit closing the
Remote Unit door, which can result in damage to the cables.
Figure 22. Cable Connections for HDM RF Modules
Table 13 l
ists how to correctly connect HDM RF Modules to the Antenna ports on the bottom of the Remote Unit.
Table 13.
HDM Antenna Port Mapping
RF Module Catalog # Description TX0/RX0 TX1/RX1
20W 700 lABC Module, MIMO HDM, Single-Bay Path 1 Path 2
20W 700 uC Module, MIMO HDM, Single-Bay Path 1 Path 2
20W 700 lABC/700uC, Dual, Single-Bay 700 lABC 700 uC
20W 800 MIMO, Single Bay, with two External Filters Path 1 Path 2
20W 800 SMR/ 1900 PCS, Dual RF Module 1900 800
20W 850 DUAL, MIMO, Single Bay Path 1 Path 2
20W 850 Cell/1900 PCS, Dual, Single-Bay 1900 850
20W 1900 PCS Dual MIMO, Single-Bay Path 1 Path 2
20W 1900/2100 Dual, Single Bay 2100 1900
20W HDM AWS Band 4 MIMO, Single-Bay Path 1 Path 2
(1) A 20W 800 SMR/ 1900 PCS, Dual RF Module RF Mod
ule (FWP-441T841MOD) requires a FlexWave Notch
Filter (FWP-SPRINTFILTER) between the Remote Unit and the antenna to provide protection from spurious
emissions in the Public Safety band below 861.35 MHz and the Cellular band above 869.5 MHz. Information
on how to install the Notch Filter is provided in “FlexWave Notch Filter (FWP-SPRINTFILTER)” on page 47.
FWP-L4MT000MOD
FWP-U4MT000MOD
FWP-L4MTU4MMOD
FWP-44MT000MOD
FWP-441T841MOD
(1)
FWP-B4MT000MOD
FWP-C4MT000MOD
FWP-84MT000MOD
FWP-84MTA4MMOD
FWP-A4MT000MOD