Page 38 FlexWave Prism Remote Unit RF Module Installation Guide
©2015 TE Connectivity TECP-77-141 Issue 8 300001744178 Rev H August 2015
d Connect the Power cable to the PWR receptacle of the RF Module.
i Ensure
that the DC power switch that corresponds to the bay(s) in which the RF Module is to be
installed is in the Off position (see “Check the DC Power Switch for the Module Bay” on page 24).
i Insert the Power cable into the PWR connector, and slide it in until fully seated. Full insertion can be
recognized by an audible click as the Power cable Connector locks into the RF Module Receptacle.
ii Verify that the Power cable is fully seated by lightly pulling back on it while making sure to not
depress the release triggers on the ends of the connector. When fully inserted, the cable should not
be able to be removed from the receptacle.
4 Repeat all the steps in “Install the RF Module(s)” on page 21 to install other RF Modules.
Bay A
Bay D
Bay C
Bay B
SeRF
Module
TX0/RX0
TX1/RX1
DIV
PRIM
PWR
Note roung of
high-speed cables
Note bend
radii ≥ 1-inch
Edge of Connector Interface Panel
Cable connecons for a Single-Slot RF Module
Figure 21. Cable Connections for Single-Bay RF Modules