- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Standards Certification
- Accessing User Documentation on the TE Customer Portal
- Contacting TE Connectivity
Page 36 FlexWave Prism Remote Unit RF Module Installation Guide
©2015 TE Connectivity TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015
Latches on Legacy Dual-Bay 40W RF Modules
For Legacy Dual-Bay 40W RF Modules, secure four latches, as shown in Figure 20.
Four latches in a
Legacy Dual-Slot 40W
RF Module
Figure 20. Legacy Dual-Bay 40W RF Module Latches
Verify that the RF Module Mounting Hook is Engaged
Verify that the RF Module Mounting Hook is engaged correctly by pulling the module away from the heat sink.
The RF Module should not move. If the RF Module moves during this check, repeat all the steps starting at “Install
the RF Module into the Prism Remote Chassis” on page 26 through this step.
Connect the RF Module Cables to the PRU Chassis
The steps to connect the RF Module cables have been separated into two different procedures; follow the steps
that correspond to the RF Module being installed.
• “Connecting Cables in a Single-Bay RF
Module Installation” on page 37
• “Conn
ecting Cables in a Dual-Bay RF Module Installation” on page 40.