User's Manual
Table Of Contents
- Document Overview
- Overview of RF Modules for Prism Remote Units
- RF Module Components
- RF Group Assignments for PRU RF Module Bays
- Understanding RF Cable Rules
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Standards Certification
- Accessing User Documentation on the TE Customer Portal
- Contacting TE Connectivity
Page 30 FlexWave Prism Remote Unit RF Module Installation Guide
©2015 TE Connectivity TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015
3 Align the Mounting Hook on the module with the receiving flange on the PRU heat sink, and then slide the RF
Module in toward the flange until it can go no further.
RF Module
Mounng
hook
Chassis
Receiving
flange
Mounng Bracket at
back of the PRU
(View is looking down into the
PRU chassis from the top.)
4 Push the left edge of the RF Module back and into the PRU chassis until it can go no further, as shown in the
following graphics:
• For Single-Bay R
F Modules, see Figure 15 on page 31.
• For HDM RF Modul
es, see Figure 16 on page 32.
• Fo
r Dual-Bay RF Modules, see Figure 17 on page 33, which uses the Legacy Dual-Bay 40W RF Module as
an example.
CAUTION! Make sure the RF Module is seated correctly in
the Module shelf. Incorrect alignment of the RF Module
can cause the RF Module to fail due to overheating.
• The front edge of the RF Module should be parallel with the shelf above it.
• The Mounting Hook on the RF Module should be fully engaged with the Receiving f
lange on the
Remote Unit chassis.
• An incorrectly seated RF Module makes closing the Prism door difficu
lt. If you later cannot shut the
Remote Unit door, verify that the RF Module is installed correctly.