User's Manual
Table Of Contents
- Document Overview
- Overview of RF Modules for Prism Remote Units
- RF Module Components
- RF Group Assignments for PRU RF Module Bays
- Understanding RF Cable Rules
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Standards Certification
- Accessing User Documentation on the TE Customer Portal
- Contacting TE Connectivity
Page 26 FlexWave Prism Remote Unit RF Module Installation Guide
©2015 TE Connectivity TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015
Install the RF Module into the Prism Remote Chassis
1 Hold the RF Module so that the DART card(s) face away from the PRU and the Mounting Hook is toward the
Receiving flange on the PRU chassis.
NOTE: Always install RF Modules from the
bottom up. Do not skip a bay, as this provides more efficient heat
dissipation.
2 Holdin
g the RF Module at a 45° angle in respect to the rear heatsink, rest the bottom surface of the module
on the RF Module shelf, as shown in one of the following graphics, and as applicable to the RF Module.
• Sing
le-Bay RF Module: Figure 11 on page 26
• HDM R
F Module: Figure 12 on page 27
• Dual-Bay RF Modu
le: Figure 13 on Page 28
• Le
gacy Dual-Bay 40W RF Module: Figure 14 on Page 29.
Bay C
Bay D
SeRF
Module
Bay A
Bay B
Single-Slot
RF Module
Heat Sink
Figure 11. Installing a Single-Bay RF Module