User's Manual
Table Of Contents
- Document Overview
- Overview of RF Modules for Prism Remote Units
- RF Module Components
- RF Group Assignments for PRU RF Module Bays
- Understanding RF Cable Rules
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Check the DC Power Switch for the Module Bay
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables to the PRU Chassis
- Power on the RF Module(s) and the Prism Remote Unit
- Close the Remote Unit Door and Solar Shield
- Provision the Prism Remote Unit
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Standards Certification
- Accessing User Documentation on the TE Customer Portal
- Contacting TE Connectivity
Page 24 FlexWave Prism Remote Unit RF Module Installation Guide
©2015 TE Connectivity TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015
For HDM RF Modules, the thermal pads are located as listed below and as shown in Figure 10.
• one pad for each Rx and Tx board
• one large pad over the DPM
• on
e for each Power Amplifier (PA), which is on the bottom of the HDM RF Module.
DPM Thermal Pad
Tx A Thermal Pad
Tx B Thermal Pad
Rx A Thermal Pad
Rx B Thermal Pad
2.9796 in2.9796 in
NOTE: Tx and Rx cards are paired: Tx A ony pairs with Rx A and Tx B only pairs with Rx B.
Figure 10. Thermal Pads on an HDM RF Module
Check the DC Power Switch for the Module Bay
DC Power switch for Bay A
DC Power switch for Bay B
DC Power switch for Bay C
DC Power switch for Bay D
Ensure that the DC power switch that
corresponds to the bay(s) in which the RF Module
i
s to be installed is in the Off position (see graphic
to the right).