User's Manual
Table Of Contents
- Document Overview
- Overview of RF Modules for Prism Remote Units
- RF Module Components
- Understanding the RF Module Cables
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables
- Power on the RF Module
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Standards Certification
- Accessing User Documentation on the TE Customer Portal
- Contacting TE Connectivity
FlexWavePrismRemoteUnitRFModuleInstallationGuide Page39
TECP‐77‐141Issue6 • 300001744178RevF • July2014 ©2014TEConnectivity
ConnectingCablesinaDual‐BayRFModuleInstallation
1 PositionthecablessothattheyareundertherightedgeoftheRFModule,pointingup.
2 Fol
lowtheruleslistedin“UnderstandingtheRFModuleCables”onpage14.
3 Fol
lowtheruleslistedbelow;theserulesareapplicableonlytoDual‐BayRFModules.
• Table13listshowtocorrectlyconnectHDMRFModulesto
theAntennaportsonthebottomofthePRU.
Table13.
HDMAntennaPortMapping
RFModuleCatalog# Description TX0/RX0 TX1/RX1
DUAL20WSMR800/PCS1900 1900 800
HDMMIMO20W1900PCSRFMO
DULE Path1 Path2
HDMMIMO20W2100AW
SRFMODULE Path1 Path2
HDMDUAL20W850/
1900RFMODULE 1900 850
HDMMIMO20W700LOWERABCRFMOD
ULE Path1 Path2
HDMDUAL20W,700ABC/700UC,RFMODU
LE 700lABC 700uC
HDMMIMO20W700UPPERCMODULE Path1 Path2
(1) ADual20WSMR800/PCS
1900RFModule(FWP‐441T841MOD)requiresaFlexWaveNotchFilter
(FWP‐SPRINTFILTER)betweenthePRUandtheantennatoprovideprotectionfromspuriousemissions
inthePublicSafetybandbelow861.35MHzandtheCellularbandabove869.5MHz.Informationon
howtoinstalltheNot
chFilterisprovidedin“FlexW aveNotchFilter(FWP‐SPRINTFILTER)”onpage44.
• TheupperRFModuleshelfwilleithernotbepresent(factoryinstalledmodule)orwillberemovedprior
toinstallation(fieldinstalledmodule).
• The
MODNTX0/RX0cableforthelowerRFModulebaywillneedtobeconnectedtotheMODNTX0/RX0
N‐StyleRFconnectionoftheDual‐BayRFModule.
• ConstraintheMOD
NTX1/RX1cabletotheexistingcablesusingatiewrapsuchsoitcannotbepinched
orpreventthePRUdoorfromclosing.DonotcutorattempttootherwiseremovethisRFcable.
• TheRFcab
lesandtwoLVDScablesofthelowerRFModulebayarenotusedwheninstallingaDual‐Bay
RFModule.
4 Workingfromthebo
ttomconnectorup,connecttheRFModulecables,asfollows:
a Con
necttheMODNTX1/RX1cabletotheRFModule.
i Con
straintheMODNTX1/RX1cableofthelowerRFModulebaytoaccompanyingcablesusingatie
wrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.
ii ConnecttheMODNTX1/RX1cabletotheTX1/RX1orN/C,N‐StyleJackoftheupperRFModulebay.
iii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
iv Torquecouplingnutto8±1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnlossand
higherthannormalVSWRreportedbythesystem.
FWP‐ 441T841MOD
(1)
FWP‐ 84MT000MOD
FWP‐ A4MT00
0MOD
FWP‐ C4MT000MOD
FWP‐ L4MT000MOD
FWP‐ L4MTU4MMOD
FWP‐ U4MT000MOD