User's Manual

Page36 FlexWavePrismRemoteUnitRFModuleInstallationGuide
©2014TEConnectivity TECP77141Issue6 300001744178RevF July2014
ConnectingCablesinaSingleBayRFModuleInstallation
1 PositionthecablessothattheyareundertherightedgeoftheRFModule,pointingup.
2 Followtheruleslistedin“UnderstandingtheRFModuleCables”onpage14.
3 ConnecttheRFModulecables,inthefollowingorder:
a ConnecttheMODNTX0/RX0cabletotheRFModule.
i InserttheN‐StylePlugoftheMODNTX0/RX0cableintotheTX0/RX0N‐StyleJackoftheRFModule.
ii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
iii Torquecouplingnutto8±1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnlossand
higherthannormalVSWRreportedbythesystem.
b ConnecttheMODNTX1/RX1cabletotheRFModule.
i IfaTX1/RX1RFModuleconnectionisavailable,inserttheN‐StylePlugoftheMODNTX1/RX1cable
intotheTX1/RX1NStyleJackoftheRFModule.IfRFModuleconnectionisnotavailable,constrain
theMODNTX1/RX1cabletoaccompanyingcablesusingatiewrapsoitcannotbepinchedorprevent
thePRUdoorfromclosing.
ii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
iii Torquecouplingnutto8±1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnlossand
higherthannormalVSWRreportedbythesystem.
c ConnecttheLVDSCablestotheRFModule.
i ConnecttheMODNDIVLVDSCabletotheDIVreceptacleoftheRFModulebyinsertingandsliding
inuntilfullyseated.
NOTE: AlwaysconnecttheDiversityLVDSCablewiththeRFModule.
ii ConnecttheMODNPRIMLVDSCabletothePRIMconnector,followingthesamestepsasabove.
NOTE: FullinsertioncanberecognizedbyanaudibleclickastheLVDSCableConnectorlocksintotheRF
ModuleReceptacle.ThiscanbeverifiedbylightlypullingbackontheLVDSconnectorwhilemakingsure
notto
depressthereleasetrigger.Whenfullyinserted,thecableshouldnotbeabletoberemovedfrom
thereceptacle.
d ConnectthePowerCableConnectortothePWRreceptacleoftheRFModulebyinsertingandslidingin
untilfullyseated.
NOTE: FullinsertioncanberecognizedbyanaudibleclickasthePowerCableConnectorlocksintotheRF
ModuleReceptacle.ThiscanbeverifiedbylightlypullingbackonthePowerCableConnectorwhile
makingsurenottodepressthereleasetriggersontheendsoftheconnector.Whenfullyinserted,
the
cableshouldnotbeabletoberemovedfromthereceptacle.