FlexWavePrismRemoteUnitRFModuleInstallationGuide Page25
TECP‐77‐141Issue6 • 300001744178RevF • July2014 ©2014TEConnectivity
InstalltheRFModuleintothePrismRemoteChassis
1 HoldtheRFModulesothattheDARTcard(s)faceawayfromthePRUandtheMountingHookistowardthe
ReceivingflangeonthePRUchassis.
NOTE: AlwaysinstallRFModulesfromthebo
ttomup.Donotskipabay,asthisprovidesmoreefficientheat
dissipation.
2 Holdingthe
RFModuleata45°angleinrespecttotherearheatsink,restthebottomsurfaceofthemodule
ontheRFModuleshelf,asshowninoneofthefollowinggraphics,andasapplicabletotheRFModule.
• Single‐BayRFModule:Figure11onpage25
• HDMR
FModule:Figure12onpage26
• Dual‐BayRFMo
dule:Figure13onPage27
• Le
gacyDual‐Bay40WRFModule:Figure14onPage28.
Bay C
Bay D
SeRF
Module
Bay A
Bay B
Single-Slot
RF Module
Heat Sink
Figure11.InstallingaSingle‐BayRFModule