Installation Guide

Install the RF Module(s)
Page 42 FlexWave Prism RF Modules for Prism Remote Units Installation Guide
© 2013 TE Connectivity Ltd TECP-77-141 Issue 5 300001744178 Rev E November 2013
c ConnecttheLVDSCablestotheRFModule.
i Ifavailable,connecttheMODNDIVLVDSCabletotheDIVreceptacleofthelowerRF
Modulebyinsertingandslidinginuntilfullyseated.IfDIVreceptacleisnotavailable,
constraintheMODNDIVLVDSCabletoaccompanyingcablesusingatiewrapsoit
cannotbepinchedorpreventthePRUdoorfromclosing.
ii Ifavailable,connecttheMODNPRIMLVDSCabletothePRIMreceptacleofthelower
RFModulebyinsertingandslidinginuntilfullyseated.IfDIV receptacle is not
available,constraintheNPRIMLVDSCabletoaccompanyingcablesusingatiewrap
soitcannotbepinchedorpreventthePRUdoorfromclosing.
iii Ifavailable,connecttheMODNDIVLVDSCabletotheDIVreceptacleoftheupperRF
Modulebyinsertingandslidinginuntilfullyseated.IfDIVreceptacleisnotavailable,
constraintheMODNDIVLVDSCabletoaccompanyingcablesusingatiewrapsoit
cannotbepinchedorpreventthePRUdoorfromclosing.
iv Ifavailable,connecttheMODNPRIMLVDSCabletothePRIMreceptacleoftheupper
RFModulebyinsertingandslidinginuntilfullyseated.IfDIV receptacle is not
available,constraintheNPRIMLVDSCabletoaccompanyingcablesusingatiewrap
soitcannotbepinchedorpreventthePRUdoorfromclosing.
NOTE: Fullinsertion canberecognizedbyanaudibleclickastheLVDSCableConnectorlocksintotheRF
Module Receptacle. This can be verified by lightly pulling back on the LVDS connector while
makingsurenottodepressthereleasetrigger.Whenfullyinserted,thecableshouldnotbeable
to
beremovedfromthereceptacle.
d ConnectthePowercabletotheRFModule.
i ConnectthePowerCableConnectortothePWRreceptacleofthelowerRFModuleby
insertingandslidinginuntilfullyseated.
ii Ifavailable,connectthePowerCableConnectortothePWRreceptacleoftheupperRF
Modulebyinsertingandslidinginuntilfullyseated.IfPWRreceptacleisnotavailable,
constrainthePowerCabletoaccompanyingcablesusingatiewrapsoitcannotbe
pinchedorpreventthePRUdoorfromclosing.
NOTE: FullinsertioncanberecognizedbyanaudibleclickasthePowerCableConnectorlocksintothe
RFModuleReceptacle.ThiscanbeverifiedbylightlypullingbackonthePowerCableConnector
whilemakingsurenottodepressthereleasetriggersontheendsoftheconnector.When fully
inserted,
thecableshouldnotbeabletoberemovedfromthereceptacle.
RefertothegraphicthatcorrespondstotheRFModulebeinginstalledinadual‐slot:
Dual‐BayDual‐SlotRFModule:Figure23onPage43
Dual‐Slot40WRFModule:Figure24onPage44.