Installation Guide
Table Of Contents
- Preface
- Overview of RF Modules for PRUs
- RF Module Components
- Understanding the RF Module Cables
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Dual-Slot Modules Only—Remove the Module Slot Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables
- Power on the RF Module
- Contacting TE Connectivity
Connect the RF Module Cables
FlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 41
TECP-77-141 Issue 5 • 300001744178 Rev E • November 2013 © 2013 TE Connectivity Ltd.
4 Workingfromthebottomconnectorup,connecttheRFModulecables,asfollows:
a ConnecttheMODNTX1/RX1cabletotheRFModule.
NOTE: DonotremoveanyfactoryconnectedRFCables.
i
ConstraintheMODNTX1/RX1cableofthelowerRFModuleslottoaccompanying
cablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.
ii ConnecttheMODNTX1/RX1cabletotheTX1/RX1orN/C,N‐StyleJackoftheupper
RFModuleslot.
iii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
iv Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnloss
andhigherthannormalVSWRreportedbythesystem.
b ConnecttheMODNTX0/RX0cabletotheRFModule.
NOTE: DonotremoveanyfactoryconnectedRFCables.
i
IfTX0/RX0RFModuleconnectionisavailable,inserttheN‐StylePlugoftheMODN
TX0/RX0cableintotheTX0/RX0N‐StyleJackofthelowerRFModule slot. If RF
Module connection is not available, constrain the MOD N TX0/RX0cableto
accompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoor
fromclosing.
ii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
iii Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.
iv IfTX0/RX0RFModuleconnectionisavailable,inserttheN‐StylePlugoftheMODN
TX0/RX0cableintotheTX0/RX0N‐StyleJackoftheupperRFModule slot. If RF
Module connection is not available, constrain the MOD N TX0/RX0cableto
accompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoor
fromclosing.
v Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
vi Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnloss
andhigherthannormalVSWRreportedbythesystem.