Installation Guide

Connect the RF Module Cables
FlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 41
TECP-77-141 Issue 5 300001744178 Rev E November 2013 © 2013 TE Connectivity Ltd.
4 Workingfromthebottomconnectorup,connecttheRFModulecables,asfollows:
a ConnecttheMODNTX1/RX1cabletotheRFModule.
NOTE: DonotremoveanyfactoryconnectedRFCables.
i
ConstraintheMODNTX1/RX1cableofthelowerRFModuleslottoaccompanying
cablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.
ii ConnecttheMODNTX1/RX1cabletotheTX1/RX1orN/C,N‐StyleJackoftheupper
RFModuleslot.
iii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
iv Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnloss
andhigherthannormalVSWRreportedbythesystem.
b ConnecttheMODNTX0/RX0cabletotheRFModule.
NOTE: DonotremoveanyfactoryconnectedRFCables.
i
IfTX0/RX0RFModuleconnectionisavailable,inserttheNStylePlugoftheMODN
TX0/RX0cableintotheTX0/RX0NStyleJackofthelowerRFModule slot. If RF
Module connection is not available, constrain the MOD N TX0/RX0cableto
accompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoor
fromclosing.
ii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfingertighten.
iii Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.
iv IfTX0/RX0RFModuleconnectionisavailable,inserttheNStylePlugoftheMODN
TX0/RX0cableintotheTX0/RX0NStyleJackoftheupperRFModule slot. If RF
Module connection is not available, constrain the MOD N TX0/RX0cableto
accompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoor
fromclosing.
v Turnthecouplingnutoftheplugclockwisetothreadontothejackandfingertighten.
vi Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnloss
andhigherthannormalVSWRreportedbythesystem.