Connect the RF Module Cables
FlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 39
TECP-77-141 Issue 5 • 300001744178 Rev E • November 2013 © 2013 TE Connectivity Ltd.
RefertothegraphicthatcorrespondstotheRFModulebeinginstalledintoasingleslot(bay)
ofthePRU:
• Single‐SlotRFModule:Figure21onPage39
• HDMRFModule:Figure22onpage40
Figure21.Cable Connections for Single-Slot RF Modules
CAUTION! EnsurethatallcablebendsarebelowthetopedgeoftheConnectorInterfacePanelasindicated
bythedashedlineintheprecedingfigure.Failuretocorrectlypositionthecablescouldinhibit
closingthePRUdoor,whichcanresultindamagetothecables.
MOD A
MOD D
MOD C
MOD B
SeRF
Module
TX0/RX0
RX1
DIV
PRIM
PWR
Note routing of
high-speed cables
Note bend
radii ≥ 1-inch
Edge of Connector Interface Panel
Cable connections for a Single-Slot RF Module