Install the RF Module(s)
Page 38 FlexWave Prism RF Modules for Prism Remote Units Installation Guide
© 2013 TE Connectivity Ltd TECP-77-141 Issue 5 • 300001744178 Rev E • November 2013
ConnectingCablesinaSingle‐SlotRFModuleInstallation
1 PositionthecablessothattheyareundertherightedgeoftheRFModule,pointingup.
2 Followtheruleslistedin“UnderstandingtheRFModuleCables”onpage15.
3 Workingfromthebottomconnectorup,connecttheRFModulecables,asfollows:
a ConnecttheMODNTX1/RX1cabletotheRFModule.
i IfaTX1/RX1RFModuleconnectionisavailable,inserttheN‐StylePlugoftheMODN
TX1/RX1cableintotheTX1/RX1N‐StyleJackoftheRFModule.If RF Module
connection is not available, constrain the MOD N TX1/RX1 cable to accompanying
cablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.
ii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
iii Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnloss
andhigherthannormalVSWRreportedbythesystem.
b ConnecttheMODNTX0/RX0cabletotheRFModule.
i InserttheN‐StylePlugoftheMODNTX0/RX0cableintotheTX0/RX0N‐StyleJackof
theRFModule.
ii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.
iii Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.
NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnloss
andhigherthannormalVSWRreportedbythesystem.
c ConnecttheLVDSCablestotheRFModule.
i Connect the MOD N DIV LVDS Cable to the DIV receptacle of the RF Module by
insertingandslidinginuntilfullyseated.
NOTE: AlwaysconnecttheDiversityLVDSCablewiththeRFModule.
ii
ConnecttheMODNPRIMLVDSCabletothePRIMconnector,followingthesamesteps
asabove.
NOTE: Fullinsertion canberecognizedbyanaudibleclickastheLVDSCableConnectorlocksintotheRF
Module Receptacle. This can be verified by lightly pulling back on the LVDS connector while
makingsurenottodepressthereleasetrigger.Whenfullyinserted,thecableshouldnotbeable
to
beremovedfromthereceptacle.
d ConnectthePowerCableConnectortothePWRreceptacleoftheRFModulebyinserting
andslidinginuntilfullyseated.
NOTE: FullinsertioncanberecognizedbyanaudibleclickasthePowerCableConnectorlocksintothe
RFModuleReceptacle.ThiscanbeverifiedbylightlypullingbackonthePowerCableConnector
whilemakingsurenottodepressthereleasetriggersontheendsoftheconnector.When fully
inserted,
thecableshouldnotbeabletoberemovedfromthereceptacle.