Installation Guide

Install the RF Module(s)
Page 32 FlexWave Prism RF Modules for Prism Remote Units Installation Guide
© 2013 TE Connectivity Ltd TECP-77-141 Issue 5 300001744178 Rev E November 2013
4 PushtheleftedgeoftheRFModulebackandintothePRUchassisuntilitcangonofurther,as
showninthefollowinggraphics:
ForSingle‐SlotRFmodules,seeFigure15onpage32.
ForHDMRFmodules,seeFigure16onpage33.
ForDual‐SlotRFmodules,seeFigure17onpage34,whichusestheDual‐Slot40WRF
Moduleasanexample.
CAUTION! MakesuretheRFModuleisseatedcorrectlyintheModuleshelf.IncorrectalignmentoftheRF
ModulecancausetheRFModuletofailduetooverheating.
•ThefrontedgeoftheRFModuleshouldbeparallelwiththeshelfaboveit.
•TheMountingHookontheRFModuleshouldbefullyengagedwiththeReceivingflangeon
thePRUchassis.
•IfyoulatercannotshutthePRUdoor,verifythattheRFModuleisinstalledcorrectly.
Figure15.Seating a Single-Slot RF Module
Push the RF Module
back into the chassis
until it can go no further.
Single-Slot
RF Module