RF Module Components
Page 14 FlexWave Prism RF Modules for Prism Remote Units Installation Guide
© 2013 TE Connectivity Ltd TECP-77-141 Issue 5 • 300001744178 Rev E • November 2013
NOTE: IndustryCanada20dBPassBandModelNumberFWP‐C4MT000MODCellular
850MHz=26.3MHzandthePCS1900=66.8MHz.
DigitalProcessingModule
TheDigitalProcessingModule(DPM)isfoundonlyintheHDMRFModules.TheDPMprovides
theprimaryprocessingandlogicfunctionsfortheHDMRFModule.Italsoprovidestheprimary
powerinterfacefortheHDMRFModule,andconversionofthenative28
Vdcvoltagetolower
voltagesasnecessaryforfunctionality.
TheDPMhasaTransmit(Tx)BoardandaReceive(Rx)Board:
• TxBoard—providesbandspecificfilteringfortheintendedTransmitpath.
• RxBoard—providesbandspecificfilteringfortheintendedReceivepath.
Table6. LPAMaximumCompositeTxPowerLevelsforDual‐Slot40WRFModules
Passband Maximum
dBm
Watts Instantaneous
Bandwidth (MHz)
PCS 1900 +46 40 70
AWS 2100 +46 40 45