Installation Manual
Table Of Contents
- Document Overview
- Overview of RF Modules for Prism Remote Units
- RF Module Components
- Understanding the RF Module Cables
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables
- Power on the RF Module
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Standards Certification
- Accessing User Documentation on the TE Customer Portal
- Contacting TE Connectivity
FlexWavePrismRemoteUnitRFModuleInstallationGuide Page7
TECP‐77‐141Issue6 • 300001744178RevF • July2014 ©2014TEConnectivity
RFModuleDARTs
EachRFModulecansupportanyofthefollowingDARTcombinations:
• oneClassicDARTo
roneSingleSuperDART
• two
ClassicDARTs(i.e.,the6.5W800/900ESMRModule,Non‐Diversity,Classic)
• twoClassic
DARTs—Diversity
• twoSingleSuperDARTs—Diversity
• oneDualSu
perDART
• oneortwosetsofTxorRxBoards
(HDM).
EachRFModulewillhaveuptotwo6‐timeslotDARTsorone12‐time
slotDARTperRFModule.
TheDARTtypedeterminesthemaximumnumberoflinks,wherether
ecanbeuptoeightClassicDARTsorSingle
SuperDARTsthatsupport39MHzeach,orupto4DualSuperDARTsthatsupportupto75MHzeach.
PrismsupportstheDARTModuletyp
eslistedbelow.
• Classic
DARTsare6‐timeslotDARTsthatsupportupto35MHzcontiguousbandwidth(seeTable4on
page7).
• Single
SuperDARTsare6‐timeslotDARTsthatsupporttwonon‐contiguousbandsintheentirefrequency
rangeoftheDART,butcannotexceed39MHztotalRFbandwidth(seeTable5onpage7).
• Dual
SuperDARTsare12‐timeslotDARTsthatsupportupto60‐75MHz(seeTable6onpage8)
Table4.
Single‐BayClassicDARTs
DARTModuleType MaximumBandwidth(MHz) NumberofFiberSlots
800AP
ACiDENClassic 19 3
800SMRClassic 18 3
850Ce
llClassic 25 4
900SMRClassic 5 1
Table5. Single‐BaySuperDARTs
(1)
DARTName Usedin… Maximum
Frequency
Span(MHz)
Maximum
Bandwidth
(MHz)
Maximum
Fiber
Slots
HostUnits HEUs
1800GSMSGLSu
perDART Yes No 75 39 6
1900PCSSG
LSuperDART Yes Yes 70 39 6
2100AW
SSGLSuperDART Yes Yes 45 39 6
2100UMTSSG
LSuperDART Yes No 60 39 6
700IA
BCSGLSuperDART Yes Yes 18 18 3
700uCSGLSup
erDART Yes Yes 10 10 2
900EGSMSGLSup
erDART Yes No 35 35 6
(1) Whenus
ingaHostUnitwithboththeSeRFIIandSystemBoardIImodules,thebandwidthsandfiberslotsshownareonly
availableinHostUnitDARTSlots1and3forSingle‐BaySuperDARTs.
NOTE: IndustryCanadaPCS20dBnominalbandwidthislessthan61.5MHz.
NOTE: IndustryCanadaAWS20dBnominalbandwidthislessthan47.2MHz