Installation Manual
Table Of Contents
- Document Overview
- Overview of RF Modules for Prism Remote Units
- RF Module Components
- Understanding the RF Module Cables
- Install the RF Module(s)
- Safety Precautions
- Guard against Damage from Electro-Static Discharge
- Unpack and Inspect the RF Module
- Remove Release Liners from the RF Module
- Dual-Bay Modules Only—Remove the Module Bay Shelf
- Install the RF Module into the Prism Remote Chassis
- Secure RF Module Latches
- Connect the RF Module Cables
- Power on the RF Module
- FlexWave Notch Filter (FWP-SPRINTFILTER)
- Standards Certification
- Accessing User Documentation on the TE Customer Portal
- Contacting TE Connectivity
FlexWavePrismRemoteUnitRFModuleInstallationGuide Page21
TECP‐77‐141Issue6 • 300001744178RevF • July2014 ©2014TEConnectivity
GuardagainstDamagefromElectro‐StaticDischarge
CAUTION! Electro‐StaticDischarge(ESD)candamageelectroniccomponents.TopreventESDdamage,alwayswearanESD
wriststrapwhenworkingwithaPrismRemoteUnitorwhenhandlinganyofitscomponents—includingtheRF
Modules.ConnectthegroundwireontheESDwriststraptoanearthgroundsourcebeforetouching
thePrism
RemoteUnitoranyofitscomponents.WearthewriststraptheentiretimethatyouworkwiththePrism Remote
Unitanditscomponents.
CAUTION! PlacePrismRFModulesinanti‐staticpackingmaterialwhentransportingorstoringthem.
UnpackandInspecttheRFModule
1 Inspecttheexterioroftheshippingcontainer(s)forevidenceofroughhandlingthatmayhavedamagedthe
componentsinthecontainer.
2 Unpackeachcontainerwhilecarefullycheckingthecontentsfordamageandverifywiththepackingslip.
3 Ifdamageisfoundorpartsaremissing,fileaclaimwiththecommercialcarrierandnotifyTECustomer
Service(see
“ContactingTEConnectivity”onpage48).Savethedamagedcartonsforinspectionbythecarrier.
4 Saveallshippingcontainersforuseiftheequipmentrequiresshipmentatafuturedate.
CAUTION! HandletheRFMo dule withcareduringinstallation.Beespeciallycarefultonotdamagethethermal‐interface
material(TIM),whichisattachedtothe LPA.IftheTIMisdamaged,theLPAcanoverheat.BeforeinstallingtheRF
Module,checktoseeiftheheatsinkmaterialisgougedorcracked.If
theTIMisdamaged,donotinstalltheRF
ModuleandcontactTEConnectivityforassistance(see
“ContactingTEConnectivity”onpage48forcontact
information).
CAUTION! Ifthethermal‐interfacematerialisdamaged,theinstallationanduseoftheRFModulemayvoidthewarrantyof
theRFModule.