Alarms
FlexWave Prism Element Management System 7.1 User Manual Page 201
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
Contact Alarms—Host System Card
Alarm: Host Major Contact Alarm Output Active
Trap:
fwuHstContactAlarmOutput1
Alarm Code: AC41
Definition: User configurable Major Contact Alarm Output active.
Remedy: Check for any major alarms (Alarms > View Current Alarms). Follow the
remedies for those alarms.
Alarm: Host Minor Contact Alarm Output Active
Trap:
fwuHstContactAlarmOutput2
Alarm Code: AC42
Definition: User configurable Minor Contact Alarm Output active.
Remedy: Check for any minor alarms (Alarms > View Current Alarms). Follow the
remedies for those alarms.
Alarm: Host Contact Alarm Input 1
Trap:
fwuHstContactAlarmInput1
Alarm Code: AC43
Definition: Host Contact Alarm Input #1 active. Alarm level is user configurable.
Remedy: Check equipment connected to Host Contact Alarm Input 1, or check
contact polarity (that is, Normally Open or Normally Closed).
Alarm: Host Contact Alarm Input 2
Trap:
fwuHstContactAlarmInput2
Alarm Code: AC44
Definition: Host Contact Alarm Input #2 active. Alarm level is user configurable.
Remedy: Check equipment connected to Host Contact Alarm Input 2, or check
contact polarity (that is, Normally Open or Normally Closed).
Contact Alarms—Remote Unit
The following alarms can apply to the Prism Remote Unit (PRU) or the URH Remote
Unit (URU).
Alarm: Contact Alarm Input 1 Active
Trap:
fwuRemoteContactAlarmInput1
Alarm Code: AC65
Definition: Remote Unit (PRU/URU) Contact Alarm Input #1 active.
Remedy: Check equipment connected to Remote Unit (PRU/URU) Contact
Alarm Input 1, or check contact polarity (i.e., Normally Open or
Normally Closed).