User's Manual
Alarms
FlexWave Prism Element Management System 7.1 User Manual Page 199
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
Alarm: DART Temperature Low
Trap:
fwuRmtDARTLowTempFault
Alarm Code: AC100
Definition: DART temperature below operating limit.
Threshold: -40°C
Remedy: Check ambient conditions; fix low temperature conditions in the
DART's location.
Alarm: Delay Out Of Range
Trap:
fwuRmtRangingFault
Alarm Code: AC96
Definition: PRU/URU delay settings outside the valid range.
Remedy: Enter forward and reverse delay values (System Configuration > Configure
Delay) within the displayed range.
Minor Alarms—PRU/URU SeRF Modules
The following alarms apply to SeRF modules installed in a Prism Remote Unit (PRU)
or in a URH Remote Unit (URU).
Alarm: Fan Over Speed
Trap:
fwuRmtFanOverSpeedFault
Alarm Code: AC76
Definition: Fans operating above expected RPM.
Remedy: If alarm persists, then replace the Fan Module.
Alarm: Temperature Low
Trap:
fwuRmtUnderTempFault
Alarm Code: AC74
Definition: Temperature below operating limit.
Threshold: Minus 40°C
Remedy: Verify that ambient temperature is greater than -40°C; fix low
temperature condition at the location of the PRU/URU.