User's Manual
Alarms
FlexWave Prism Element Management System 7.1 User Manual Page 195
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
Major Alarms—PRU or URU LPA
The following alarms apply to LPAs installed in a Prism Remote Unit (PRU) or URH
Remote Unit (URU).
Alarm: LPA DC Fault
Trap:
fwuRmtLPADcFault
Alarm Code: AC109
Definition: PRU/URU Linear Power Amplifier (LPA) DC fault.
Remedy: Caused by internally detected problem with the LPA. Impact is loss
of RF service. Reset LPA. If alarm persists, replace the RF Module.
Alarm: LPA Disabled
Trap:
fwuRmtLPADisableFault
Alarm Code: AC105
Definition: PRU/URU Linear Power Amplifier (LPA) disabled due to an internally
detected problem. (VSWR, DC, Loop Fault, Low Power, or
Temperature High alarm).
Remedy: The LPA is disabled because of an internally detected problem.
Perform an LPA Reset. If the fault persists replace the RF Module.
Alarm: LPA Loop Fault
Trap:
fwuRmtLPALoopFault
Alarm Code: AC110
Definition: PRU/URU Linear Power Amplifier (LPA) Loop fault.
Remedy: Caused by internally detected problem with the LPA. Impact is loss
of RF service. Lower DART(s) gain by 10 dB, reset the LPA, and return
gain to previous value. If alarm persists, replace RF Module.
Alarm: LPA Low Power Fault
Trap:
fwuRmtLPALowPowerFault
Alarm Code: AC111
Definition: Internal Linear Power Amplifier (LPA) Low Power fault. Gain of one
or more internal amplifiers outside of specification).
Remedy: Caused by internally detected problem with the LPA. Impact is loss
of RF service. Reset LPA. If alarm persists, replace the RF Module.
Alarm: LPA Missing
Trap:
fwuRmtLPADetectFault
Alarm Code: AC112
Definition: Linear Power Amplifier (LPA) detection fault. LPA missing from PRU.
Remedy: Cause is faulty RF Module. Impact is loss of RF service. If alarm
persists, replace the RF Module.