Alarms
FlexWave Prism Element Management System 7.1 User Manual Page 193
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
Major Alarms—PRU/URU SFPs
The following alarms apply to SFPs installed in a Prism Remote Unit (PRU) or in a
URH Remote Unit (URU).
NOTE: Cascading Remote Units is not supported in this release. Alarms that pertain to cascaded
Remote Units are included as reference only.
Alarm: Excess Connections
Trap:
fwuRmtExcessConnFault
Alarm Code: AC134
Definition: Two or more PRU/URU connected to a single cascaded PRU/URU, or
a ninth PRU/URU connected in cascade, or there are more outgoing
fibers than incoming fibers on a PRU/URU in a cascade.
Remedy: Connect fiber optic cables per cascade connection rules. Refer to
appropriate installation guide for details.
Alarm: Fiber Connection Mismatch
Trap:
fwuRmtFiberConnMismatchFault
Alarm Code: AC133
Definition: Fiber optic cable connections between cascaded PRU/URUs not
following SFP connection rules.
Remedy: Connect fiber optic cables per cascade connection rules. Refer to
appropriate installation guide for details.
Alarm: Invalid Device Connection
Trap:
fwuRmtInvalidDevConnFault
Alarm Code: AC135
Definition: PRU/URU is connected to a DRU or vice versa.
Remedy: Ensure that cascaded Remotes are all the same type (that is, a PRU
to a PRU and a DRU to a DRU). Refer to appropriate installation guide
for details.
Alarm: Optical Over Drive
Trap:
fwuRmtSERFOptOverDriveFault
Alarm Code: AC84
Definition: SFP optical receive input power above specification.
Threshold: Threshold for IR is 1 dBm, and for LR is -9 dBm
Remedy: Reduce the optical receive level by adding optical attenuation.
Replace optical attenuator if faulty.