User's Manual

Alarms
FlexWave Prism Element Management System 7.1 User Manual Page 191
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
Alarm: REV Test Tone Low
Trap:
fwuRmtUplinkFailureDetectLowFault
Alarm Code: AC125
Definition: Reverse test tone not at expected level.
Remedy: Retry System Test (System Configuration > Perform System Test). If alarm
persists, replace the DART.
Alarm: Upconvert Fault
Trap:
fwuRmtUpconvertfailureFault
Alarm Code: AC126
Definition: Band specific alarm raised during Forward Link Monitoring on
PRU/URU.
Remedy: Retry System Test (System Configuration > Perform System Test). If alarm
persists, replace the DART.
Alarm: Upconvert Indeterminate
Trap:
fwuRmtUpconIndetFault
Alarm Code: AC129
Definition: Band specific alarm raised during Forward Link Monitoring on
PRU/URU.
Remedy: Retry System Test (System Configuration > Perform System Test). If alarm
persists, replace the DART.
Alarm: Upconverter Synthesizer Unlocked
Trap:
fwuRmtDARTUpConSynLockFault
Alarm Code: AC95
Definition: DART upconverter synthesizer unlocked.
Remedy: The DART Upconverter Synthesizer Unlocked alarm can occur during
Host reboots and DART hotswaps. If the alarm persists after 5
minutes, replace the DART.
Major Alarms—PRU/URU SeRF Modules
The following alarms apply to a SeRF module installed in a Prism Remote Unit
(PRU) or in a URH Remote Unit (URU).
Alarm: Fan Under Speed
Trap:
fwuRmtFanUnderSpeedFault
Alarm Code: AC77
Definition: Fans operating below expected RPM.
Remedy: Verify intake and exhaust vents are clear of obstructions and/or
debris. If alarm persists, replace Fan Module.