Alarm: DART Hardware Mismatch
Trap:
fwuRmtDARTHardwareMismatchFault
Alarm Code: AC98
Definition: Host DART does not support the selected passband. Fault occurs
when a Host DART is replaced with another DART of the incorrect
type.
Remedy: Install a DART that supports the selected passband. If the position of
the PRU/URU DART is to be changed to a different frequency band,
remove and clear the DART configuration (Unit Configuration > Clear DART
Configuration), install the new DART, set the passband, and establish
the new link (System Configuration > Configure DART Links).
Alarm: Downconvert Fault
Trap:
fwuRmtDownconvertfailureFault
Alarm Code: AC128
Definition: Band specific alarm raised during Reverse Link Monitoring on
PRU/URU.
Remedy: Retry System Test (System Configuration > Perform System Test). If alarm
persists, replace the DART.
Alarm: Downconverter 1 Synthesizer Unlocked
Trap:
fwuRmtDARTDwnCon1SynLockFault
Alarm Code: AC93
Definition: DART downconverter 1 synthesizer unlocked.
Remedy: The Downconverter 1 Synthesizer Unlocked alarm can occur during
Host reboots and DART hotswaps. If the alarm persists after 5
minutes, replace the DART.
Alarm: Downconverter 2 Synthesizer Unlocked
Trap:
fwuRmtDARTDwnCon2SynLockFault
Alarm Code: AC94
Definition: DART downconverter 2 synthesizer unlocked.
Remedy: The Downconverter 2 Synthesizer Unlocked alarm can occur during
Host reboots and DART hotswaps. If the alarm persists after 5
minutes, replace the DART.
Alarm: FWD Cal Tone Fault
Trap:
fwuRmtDownlinkCalToneFailureFault
Alarm Code: AC124
Definition: Forward calibration tone not at expected level.
Remedy: Retry System Test (System Configuration > Perform System Test). If alarm
persists, replace the DART.