Major Alarms—Remote Units
The following alarms apply to both the Prism Remote Unit (PRU) and the URH
Remote Unit (URU).
Alarm: Module Missing Fault
Trap:
fwuRmtModuleMissingFault
Alarm Code: AC68
Definition: A pluggable module is missing from a Remote Unit, and can be any
of the following: DART, SFP, LNA, LPA, or PD.
Remedy: Either replace the PRU/URU module or clear DART configuration (Unit
Configuration > Clear DART Configuration).
Major Alarms—PRU/URU DARTs
The following alarms apply to DARTs installed in a Prism Remote Unit (PRU) or a
URH Remote Unit (URU).
Alarm: DART DC Supply Fault
Trap:
fwuRmtDARTDCSupplyFault
Alarm Code: AC97
Definition: DART card DC supply voltages outside specification.
Remedy: If the alarm persists for 5 minutes (may be transient on startup),
replace the DART.
Alarm: DART Fault
Trap:
fwuRmtDARTFault
Alarm Code: AC101
Definition: Summary of DART Downconverter 1 Synthesizer Unlocked,
Downconverter 2 Synthesizer Unlocked, Upconverter Synthesizer
Unlocked, DC Supply Fault alarms, and DART FPGA status.
Remedy: Inspect alarms (Alarms > View Current Alarms) for
upconverter/downconverter/DC supply alarms on the PRU/URU
DART and follow the remedies for those alarms. For PRU DART
only—if none of these alarms are present, power cycle the RF Module.
If the alarm persists, replace the RF Module.