User's Manual

Alarms
FlexWave Prism Element Management System 7.1 User Manual Page 187
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
Alarm: Module Missing Fault
Trap:
fwuHstModuleMissingFault
Alarm Code: AC2
Definition: One of the Host pluggable modules is missing (DART/SFP).
Remedy: Either replace Host module or clear DART configuration (Unit
Configuration > Clear DART Configuration).
Alarm: RLM Upconvert Fault
Trap:
fwuHstRLMUpconvertFailureFault
Alarm Code: AC48
Definition: Reverse Link Monitor (RLM) fault active.
Remedy: Running System Test (System Configuration > Perform System Test) with
un-terminated Host DARTs may cause a false RLM Upconvert Fault.
Ensure that all Host DARTs are terminated before running System
Test. If alarm persists, then replace the DART.
Major Alarms—Host SeRF Modules
Alarm: Fan Fault
Trap:
fwuHstSysCardFanFault
Alarm Code: AC6
Definition: Fan not functioning.
Remedy: Verify intake and exhaust vents are clear of obstructions and/or
debris. If alarm persists, replace Fan Module.
Alarm: SeRF Fault
Trap:
fwuHstSERFFault
Alarm Code: AC10
Definition: Summary of SeRF Synthesizer Unlocked alarm and SeRF FPGA
status.
Remedy: Check for related Host SeRF alarms (Alarms > View Current Alarms). If no
SeRF alarms exist, FPGA is faulty; replace Host SeRF Module.
Alarm: SeRF Synthesizer Unlocked
Trap:
fwuHstSERFSynthAlarmFault
Alarm Code: AC9
Definition: SeRF synthesizer unlocked.
Remedy: Check Host reference clock settings (Unit Configuration > Edit Properties).
Reseat the System Module. If reference clock source is external,
verify 10 MHz clock source and connection. If reference clock source
is internal and the alarms persists, replace the Host System Module.