TROUBLESHOOTING ALARMS
This section lists and defines alarms that the FlexWave Prism EMS reports, and
provides remedies for those alarms. The MIB Trap name for each alarm is also
listed.
Major Alarms—Host Unit
Alarm: Remote Lost
Trap:
fwuHstSERFRmtLostFault
Alarm Code: AC1
Definition: Remote Unit (PRU/URU) not communicating with Host.
Remedy: Check that the PRU/URU has power and that the power switch is on.
Check that at least one Host SFP is connected to this PRU/URU and
has acceptable RX power.
Major Alarms—Host Unit DARTs
Alarm: DART DC Supply Fault
Trap:
fwuHstDARTDCSupplyFault
Alarm Code: AC28
Definition: DART card DC supply voltages outside specification.
Remedy: Check whether the Host supply voltage is in the range of 21-60 VDC.
If the voltage is correct and the alarm persists for 5 minutes (may be
transient on startup), replace the DART.
Alarm: DART Downconverter 1 Synthesizer Unlocked
Trap:
fwuHstDARTDwnCon1SynLockFault
Alarm Code: AC25
Definition: DART downconverter 1 synthesizer unlocked.
Remedy: The Downconverter 1 Synthesizer Unlocked alarm can occur during
Host reboots and DART hotswaps. If the alarm persists after 5
minutes, replace the DART.
Alarm: DART Downconverter 2 Synthesizer Unlocked
Trap:
fwuHstDARTDwnCon2SynLockFault
Alarm Code: AC26
Definition: DART downconverter 2 synthesizer unlocked.
Remedy: The Downconverter 2 Synthesizer Unlocked alarm can occur during
Host reboots and DART hotswaps. If the alarm persists after 5
minutes, replace the DART.