User's Manual
Manage Alarms
Page 180 FlexWave Prism Element Management System 7.1 User Manual
©
2011 ADC Telecommunications, Inc ADCP-77-177 • Issue 1 • July 2011
Do the following to enable/disable alarm reporting:
1 To access the Manage Alarms page, in the System Menu bar, click Alarms > Manage
Alarms.
2 In the Select list, select the Remote Unit for which you want to change the
threshold of the RF Power Low alarm.
3 In the Threshold Value box for the RF Power Low alarm, enter the new threshold,
which must be between 0 dB - 40 dB.
4 Click Apply.
Set RF Power Low Threshold
The following rules apply to setting alarm thresholds:
• Only the threshold for the RF Power Low alarm can be changed.
• Only users with Network Manager or Admin privileges can perform this
procedure.
• Alarm thresholds cannot be set through SNMP MIBs.
• If you perform a Reset to Factory Defaults, the alarm threshold values are reset;
you will need to be reconfigure the alarm threshold values, as necessary.
• Alarm threshold values are configured by unit—they cannot be set globally for
all units in the system.
Do the following to set the RF Power Low alarm threshold:
1 To access the Manage Alarms page, in the System Menu bar, click Alarms > Manage
Alarms.
2 In the Select list, select the Remote Unit for which you want to change the
threshold of the RF Power Low alarm.
3 In the Threshold Value box for the RF Power Low alarm, enter the new threshold,
which must be between 0 dB - 40 dB.
4 Click Apply.