User's Manual

Manage Alarms
Page 180 FlexWave Prism Element Management System 7.1 User Manual
©
2011 ADC Telecommunications, Inc ADCP-77-177 Issue 1July 2011
Do the following to enable/disable alarm reporting:
1 To access the Manage Alarms page, in the System Menu bar, click Alarms > Manage
Alarms.
2 In the Select list, select the Remote Unit for which you want to change the
threshold of the RF Power Low alarm.
3 In the Threshold Value box for the RF Power Low alarm, enter the new threshold,
which must be between 0 dB - 40 dB.
4 Click Apply.
Set RF Power Low Threshold
The following rules apply to setting alarm thresholds:
Only the threshold for the RF Power Low alarm can be changed.
Only users with Network Manager or Admin privileges can perform this
procedure.
Alarm thresholds cannot be set through SNMP MIBs.
If you perform a Reset to Factory Defaults, the alarm threshold values are reset;
you will need to be reconfigure the alarm threshold values, as necessary.
Alarm threshold values are configured by unit—they cannot be set globally for
all units in the system.
Do the following to set the RF Power Low alarm threshold:
1 To access the Manage Alarms page, in the System Menu bar, click Alarms > Manage
Alarms.
2 In the Select list, select the Remote Unit for which you want to change the
threshold of the RF Power Low alarm.
3 In the Threshold Value box for the RF Power Low alarm, enter the new threshold,
which must be between 0 dB - 40 dB.
4 Click Apply.