User's Manual
Alarms
FlexWave Prism Element Management System 7.1 User Manual Page 179
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
Host DART DART ALC Limiting +19 - Fwd Gain dBm
Host DART DART DC Supply Fault
Remote DART DART DC Supply Fault
Host DART DART Over Drive +19 dBm
Remote DART DART Temperature High 85 Deg C
Remote DART DART Temperature Low minus 40 deg C
Host DART DART Under Drive +5 - Fwd Gain - 20 dBm
Remote SeRF Door Open
Remote DART Downconvert Fault
Remote DART DART DC Supply Fault
Remote SFP Excess Connections
Host DART FLM Downconvert Fault
Remote DART FWD Cal Tone Fault
Remote SFP Invalid Device Connection
Remote LNA LNA Power Fault
Host SFP Optical Over Drive 1 dBm(IR)/-9dBm(LR)
Remote SFP Optical Over Drive 1 dBm(IR)/-9dBm(LR)
Host SFP Optical RX High BER 0.00001
Remote SFP Optical RX High BER 0.00001
Host SFP Optical RX No Light
Remote SFP Optical RX No Light
Host SFP Optical Under Drive -18 (IR) dBm/-27 dBm (LR)
Remote SFP Optical Under Drive -18 dBm (IR)/ -27 dBm (LR)
Remote DART REV Test Tone Low
Remote PD RF Power Low 0 dBm*
Host DART RLM Upconvert Fault
Host DART RLM Upconvert Indeterminate
Remote SeRF Software Version Mismatch Fault
Remote PD System VSWR Fault 3:1
Host SeRF Temperature High 62 Deg C
Remote SeRF Temperature High 95 Deg C
PRU/URU SeRF Temperature High 62 Deg C
Host SeRF Temperature Low 0 Deg C
Remote SeRF Temperature Low Minus 40 Deg C
PRU/URU SeRF Temperature Low 0 Deg C
Remote LPA Under Power
Remote DART Upconvert Fault
Remote DART Upconvert Indeterminate
Remote DART Uplink Inactivity Fault 10 dB above the noise floor.
* You can manually set the threshold for RF Power Low; see “Set RF Power Low Threshold” on page 180
Table 23. Alarms That Can Be Enabled/Disabled (Cont.)
Unit Module Alarm Alarm Threshold