User's Manual
Managing Units
FlexWave Prism Element Management System 7.1 User Manual Page 165
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
RESETTING AN LPA
CAUTION! Once an LPA Reset is started, Loss of Service occurs. It takes approximately 10 to 20
seconds before the LPA signal recovers. The GUI RF power reading will take longer
depending on the number of Remotes equipped—for a fully loaded Prism system with 8
Remotes the power reading could take several minutes to update.
NOTE: Only a user logged in under the admin or a Network Manager account can change Prism
system settings through the EMS.
You use the LPA Reset button to bring an LPA back into service (restart) that
stopped because of a major LPA alarm. In a dual-LPA system, resetting the LPA
applies to both LPAs at the same time.
1 To access the Configure Remote Forward Gain page, in the System Menu bar, click
System Configuration > Configure Remote Forward Gain.
2 In the Remote Id list, select the Remote Unit whose LPA you need to reset.
3 In the Remote DART list, select the DART whose LPA you need to reset.
4 Click the LPA Reset button.
5 In the LPA Reset caution dialog, click OK.