User's Manual
Managing Units
FlexWave Prism Element Management System 7.1 User Manual Page 163
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
3 In the System Tree, click the icon of the PRU/URU whose properties you want
to change.
4 In the Unit Menu bar, click Unit Configuration > Edit Properties, to open the Unit
Configuration > Edit Properties page for the selected PRU.
5 In the Capacity list, set the Capacity of the new RSI board:
• For all RSI boards installed in a URH, Capacity should always be set to 3.
• For an RSI board installed in a PRU, Capacity can be 1, 2, 3, or 4 and indicates
the number of RF Modules installed in the PRU.
6 Click Apply.
Using Telnet or ssh to Change the Remote Unit Capacity
Alternately, the capacity can be changed using Telnet or ssh.
1 Access the Edit Unit Properties page to determine the IP address for the Host
and Remote Unit(s). In the System Menu bar, click System Configuration > Edit Unit
Properties. Each row in the Edit Unit Properties table correspond to the unit
identified in the Unit Id column. Use the IP Address column to determine the IP
address for each unit.
2 Login to the Host using telnet or ssh.
3 From the Host, login to the Remote Unit using the following command,where N
is the Remote Unit ID (1 - 8): sshremote N
4 Once logged into the Remote Unit, execute the following command, where X is
the capacity (1-4): /usr/local/fwu/bin/EEPROMWriteForCapacity.sh X