User's Manual
Viewing the Status of a Remote Unit
Page 160 FlexWave Prism Element Management System 7.1 User Manual
©
2011 ADC Telecommunications, Inc ADCP-77-177 • Issue 1 • July 2011
Remote Status Table
The Remote Status table provides general status information for a Remote Unit
(PRU/URU).
• Host Lost—Host is not communicating with
PRU/URU.
• AC Power Supply Fault—Power supply is in a
failed state, or the AC power is below the
minimum required voltage.
• Temperature High—Temperature above
operating limit. Threshold is 95°C.
• Temperature Low—Temperature below
operating limit. Threshold is Minus 40°C.
• Contact Alarm Input 1 Active—Host Contact
Alarm Input #1 active.
• Fan Under Speed—Fans operating below
expected RPM.
• Contact Alarm Input 2 Active—Host Contact
Alarm Input #2 active.
• Fan Over Speed—Fans operating above
expected RPM.
• Door Open—Door open on PRU.
• SeRF Fault—Summary of SeRF Synthesizer Unlocked alarm and SeRF FPGA
status.
• Software Version Mismatch Fault—Software version on the Host and Remote Units do
not match.
Remote Unit Capacity and Temperature
The Unit Information > View Status page for Remote Units also provides unit capacity
and temperature information for the selected Remote Unit (PRU/URU).
• Capacity—the number of RF groups available to the Remote Unit.
• Temperature—The internal Temperature of the selected unit.