User's Manual

Managing Units
FlexWave Prism Element Management System 7.1 User Manual Page 159
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
PD Status Table
The PD Status table
presents status
information for the Power
Detector in a Remote
Unit. There can be
between 1 and 4 PDs
installed in a Prism
Remote Unit.
System VSWR Fault—PRU/URU VSWR measurement above specification.
RF Power Low—PRU/URU RF Output Power below minimum threshold.
Module Missing Fault—Power Detector module is missing.
Duplexer Mismatch—Configured frequency range not supported by Duplexer.
Optical Status Table
The Optical Status table
provides status
information for SFPs
installed in a Remote
Unit (PRU/URU).There
can be between 1 and 8
SFPs installed in a
Remote Unit. If a
column has no
background color, an
SFP is not installed in
that slot.
Optical RX High BER—High bit error rate (BER) detected by fiber optic receiver.
Threshold is 0.00001.
Optical RX No Light—No signal detected by optical receiver.
Optical Transmitter Fault—SFP optical transmitter failed.
Optical Over Drive—SFP optical receive input power above specification.
Thresholds are as follows:
1 dBm for IR
-9 dBm for LR.
Optical Under Drive—SFP optical receive input power below specification.
Thresholds are as follows:
-18 dBm for IR
-27 dBm for LR.
Module Missing Fault—SFP module is missing.