Managing Units
FlexWave Prism Element Management System 7.1 User Manual Page 157
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
DART Status Table
The DART Status table
presents status of the
DARTs in a Remote Unit.
There can be between 1
and 8 DARTs installed in a
Remote Unit. If a DART
column has no background
color, a DART is not
installed in that slot, as
shown below.
The DART Status table has the following elements.
DART Fault—Summary of DART Downconverter 1 Synthesizer Unlocked,
Downconverter 2 Synthesizer Unlocked, Upconverter Synthesizer Unlocked,
DC Supply Fault alarms, and DART FPGA status.
DART DC Supply Fault—DART Module DC supply voltages outside specification.
DART Hardware Mismatch—Host DART does not support the selected passband.
Fault occurs when a Host DART is replaced with another DART of the incorrect
type.
DART Temperature High—DART temperature above operating limit. Threshold is
85°C.
Delay Out Of Range—PRU/URU delay settings outside the valid range.
DART Temperature Low—DART temperature below operating limit. Threshold is
-40°C.
Module Missing Fault—DART module is missing.