VIEWING THE STATUS OF THE HOST UNIT
1 In the System Tree, click on the Host icon.
2 In the Unit Menu bar, click Unit Information > View Status.
The Unit Information > View Status page provides the following information for the
selected Host. The background of each table cell is color coded to the level of the
alarm; see
“Viewing Parameters and Alarms” on page 44. For further information
on these faults and alarms, see “Troubleshooting Alarms” on page 185.
• Module Status table—provides status information for installed DARTs, where
columns 1 through 8 correspond to the slot in which the DART resides (Column
1 = Slot 1, and so forth). If a DART column has no background color, a DART
is not installed in that slot.
– DART Fault—Summary of DART Downconverter 1 Synthesizer Unlocked,
Downconverter 2 Synthesizer Unlocked, Upconverter Synthesizer Unlocked,
DC Supply Fault alarms, and DART FPGA status.
– DART Over Drive Fault—Red indicates that the RF signal received from the
BTS/BDA is too strong. Fault threshold is +19 dBm.
– DART Under Drive Fault—DART forward RF input signal below the normal
operating limit. Fault threshold is +5 - Fwd Gain - 20
– Module Missing Fault—One of the Host pluggable modules is missing
(DART/SFP).
– DART Hardware Mismatch—Host DART does not support the selected passband.
Fault occurs when a Host DART is replaced with another DART of the
incorrect type.
• Optical Status table—shows the current usage and alarm status of the optical
ports on the Host plus the current values of some key operating parameters.