User's Manual

Viewing the Status of the Host Unit
Page 154 FlexWave Prism Element Management System 7.1 User Manual
©
2011 ADC Telecommunications, Inc ADCP-77-177 Issue 1July 2011
VIEWING THE STATUS OF THE HOST UNIT
1 In the System Tree, click on the Host icon.
2 In the Unit Menu bar, click Unit Information > View Status.
The Unit Information > View Status page provides the following information for the
selected Host. The background of each table cell is color coded to the level of the
alarm; see
“Viewing Parameters and Alarms” on page 44. For further information
on these faults and alarms, see “Troubleshooting Alarms” on page 185.
Module Status table—provides status information for installed DARTs, where
columns 1 through 8 correspond to the slot in which the DART resides (Column
1 = Slot 1, and so forth). If a DART column has no background color, a DART
is not installed in that slot.
DART Fault—Summary of DART Downconverter 1 Synthesizer Unlocked,
Downconverter 2 Synthesizer Unlocked, Upconverter Synthesizer Unlocked,
DC Supply Fault alarms, and DART FPGA status.
DART Over Drive Fault—Red indicates that the RF signal received from the
BTS/BDA is too strong. Fault threshold is +19 dBm.
DART Under Drive Fault—DART forward RF input signal below the normal
operating limit. Fault threshold is +5 - Fwd Gain - 20
Module Missing Fault—One of the Host pluggable modules is missing
(DART/SFP).
DART Hardware Mismatch—Host DART does not support the selected passband.
Fault occurs when a Host DART is replaced with another DART of the
incorrect type.
Optical Status table—shows the current usage and alarm status of the optical
ports on the Host plus the current values of some key operating parameters.