Adding an SNMP Trap Manager
1 In the System Menu bar, click System Configuration > Set SNMP Trap Managers.
2 In the Add New Trap Manager panel, do the following:
a In the IP Address box enter the IP address of the device that you want to add
as a trap receiver. The address must be in the xxx.xxx.xxx.xxx format.
b In the Port box, enter the port on the device that will receive the traps. The
normal and recommended SNMP Trap port is 162.
c In the Community box, enter a password that will allow access to the device.
The Community password must be between 6 and 20 alphanumeric characters
(usually public or private).
d In the Version list, select the trap version for the SNMP Trap Manager that
you are registering (V1 or V2c).