User's Manual
Using an SNMP Interface
FlexWave Prism Element Management System 7.1 User Manual Page 283
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
Contact Alarm
SNMP MIB:
fwuContactAlarm
Description: Hardware Assigned Name
Syntax: Display String
Access Level: Read Only
Severity
SNMP MIB:
fwuContactAlarmSeverity
Description: Severity of the alarm
Values: 2= Minor
3 = Major
Default: Minor
Syntax: Unsigned Integer
Access Level: Read-Write
Mode
SNMP MIB:
fwuContactAlarmMode
Description: Mode of the Alarm
Values: 1=Normally Closed
2 = Normally Open
Default: 2
Syntax: Unsigned Integer
Access Level: Read-Write
Alarm Name
SNMP MIB:
fwuContactAlarmName
Description: User Assigned Name
Values: Alphanumeric Characters. Except as first character, the underscore
(_) character and spaces are allowed. Must be 5 to 40 characters in
length.
Default: Blank (empty string)
Syntax: Display String
Access Level: Read-Write
Contact Alarm Enable
SNMP MIB:
fwuContactAlarmEnable
Description: Enable/Disable the contact alarm
Values: 1 = Enabled
0 = Disabled
Default: Enabled
Syntax: Unsigned Integer
Access Level: Unsigned Integer